Shanghai Xinzhuang aseptic homogenizer application field and operation process

上海皓庄无菌均质器应用领域及操作流程


上海皓庄无菌均质器应用领域及操作流程

Shanghai Xinzhuang Sterile Homogenizer special activity is underway.

Welcome new and old customers to call and order. The following are suitable fields and operating procedures for aseptic homogenizers.

Shanghai Xinzhuang Instrument Co., Ltd. Xinzhuang (LNB) brand aseptic homogenizer makes the process of extracting bacteria from solid samples very simple, just add the sample and diluent to the sterile sample bag, then sample The sample is processed by placing the bag in a slap-type homogenizer. The sterile homogenizer effectively separates the homogeneous sample of microorganisms contained within and on the solid sample, ensuring that all samples are mixed in the sterile bag. The treated sample solution can be directly sampled and analyzed without the risk of sample changes and cross-contamination.

Aseptic homogenizer application areas: food microbial analysis; homogenization of animal tissues, biological samples, cosmetics; meat, fish, vegetables, fruits, biscuits; microbial analysis of drugs.

The operation flow settings of the aseptic homogenizer are as follows:

1. Connect the power cable to the socket behind the aseptic homogenizer and plug it into the external output power socket. Turn on the power switch. The LCD display shows the factory settings. The sterile homogenizer is automatically in the standby state.

2. Check and confirm the groove along the lower edge of the aseptic homogenizer door. If it is buckled on the crossbar at the bottom of the homogenizer, turn the door handle to open the door to the maximum. The homogenized bag containing the sample and the solvent is placed in the homogenizing box, the lower edge of the homogenizing bag is not lower than the hammering plate, the edge of the homogenizing bag mouth is exposed, the door cover is not wrinkled, and then the door switch is turned, After hearing the “drop” sound (the LCD screen should display “Close”), the door is closed. At this time, the door and the upper rail are squeezed to clamp the homogenized bag to seal it.

3. Hold the upper edge of the homogenized bag with your left hand, open the homogenizer door with your right hand, take out the homogenized bag, and finish the work once. If the sample is contaminated, use a special tool to extract the homogenized bag.

4. According to the need to homogenize the sample selection panel speed and timing time, each button will have a "beep" sound prompt. Press the “Settings” setting button. At this time, the number of times of the LCD screen M1 and the number of taps flashes, indicating that the setting state is entered, and the setting button is continuously pressed, the number of taps of M1 - M1 tapping minutes - M1 tapping seconds - M2 tapping times - M2 tapping minutes - M2 tapping seconds - M3 tapping times - M3 tapping minutes - M3 tapping seconds - exiting. When pressing the “Set” button to the parameter to be adjusted, press the increase or decrease button, the parameter will be adjusted accordingly. If you press and hold 1S or longer, the number will increase or decrease continuously. If you want to exit when setting M1, you can Directly "Reset" button to exit. After the setting is completed, press the “Continuous/Cycle” button, M1-M2-M3-Cycle-M1 switches. After adjusting to the required parameters, press the on/off button, the LCD display works, and the machine runs according to the number of times the shot is played and the time.

Shanghai Xinzhuang Instrument Co., Ltd. produces a series of aseptic homogenizers, high-quality, high-performance product quality for the national colleges and universities, scientific research institutions. Perfect service makes users buy with confidence, use comfortably. Welcome new and old customers to inquire selected