Special calibration equipment for temperature (humidity) environmental test equipment â— According to JJF1101-2003, GB / T5170.2-1996, GB9452-88, JB / T5502-91 and Other calibration specifications related to temperature and humidity â— High precision temperature and humidity measurement, both Dew point calculation function â— Support and automatically identify a variety of temperature and humidity sensors, such as RTD, PT100, PT1000, 8 kinds of thermocouples â— Permanent storage of 300,000 test data â— Embedded printer real-time printing test results â— PC interface: RS232 and USB
â— Perfect software function, real-time display data curve, automatic calculation of temperature and humidity deviation, fluctuation, uniformity and F0 value, automatically generate the latest format of the original record, calibration certificate and F0 report â— Integrated temperature and humidity sensor can be in the machine and the background The software is used for individual or overall calibration operations, and supports 6-point temperature and humidity calibration, and all measurement units can be interchanged 100%
Technical Parameters:
Measuring range: temperature is -190 ℃ ~ 1600 ℃, humidity is 0 ~ 100% RH
Accuracy: Temperature 0.05% (PT100 sensor); Thermocouple is determined according to the index number;
Relative humidity (in the range of 30% ~ 90%) ≤ ± 1.5% RH
Resolution: 0.01 ℃ 0.1% RH
Stability: Temperature <0.05 ℃ / year (main unit) Humidity <0.7% RH / year Number of inspection channels: 22 channels (16, 38, 70 channels available)
Detection method: optional display size of tour, fixed point, list, etc .: 192 × 62mm LCD screen display printing method: random, regular printing optional power supply: 220V AC ± 10%; power ≤20W
Dimensions: 248 × 320 × 68mm
Weight: about 2.6kg
annex:
Four-wire platinum resistance (PT100) temperature sensor (length standard is 5 meters):
Low temperature line: the use range is -60 ~ 230 ℃, the advantages are thin line, good flexibility, waterproof, anti-corrosion, not easy to break, pass through the door of the tested equipment without affecting the seal, to ensure the accuracy of the test data The use range is -100 ~ 300 ℃, the outer diameter is 5㎜, and it is wrapped with a metal shield layer. The advantages are strong anti-interference ability, high temperature resistance, waterproof and anti-corrosion. The disadvantage is that the wire diameter is thick, which affects the tightness of the tested equipment : Use range 0 ~ 450 ℃, outer diameter is 5㎜, wrapped with metal shielding layer, the advantage is strong anti-interference ability, high temperature resistance, the disadvantage is thick wire diameter, not waterproof. Measurement accuracy: ± 0.1% + 0.05 ℃